ADW210 Multi-Channel 3 Phase Energy Meter
● Measures 4 channels of 3 phase circuits
● Measures 3 phase power, total power (active, reactive, apparent), U, I, P, Q, S, PF, F, zero sequence current, voltage/current phase angle, voltage/current degree of unbalance, etc.
● Communication: RS485(Modbus-RTU)
● Harmonic on 2nd-31st
● Multi tariff: 4 time zones 14Periods rate setting;
● Maximum Current, maximum power demand and real time Current, real time power demand;
● Record of voltage, current and power extreme of current month and last month;
● 200 event records, record the action of DIDO;
● Support over-voltage, over-current, phase failure, DI linkage and other alarm output;
● Accuracy: Class 0.5
● 12 channel Switching inputs+4 channel Switching outputs;
● 12 bits section LCD display, background light
● 12 channel external NTC temperature +4 channel residual current measurement (leakage current);
● Rated voltage: 3×220/380V
● Rated current: 5A( secondary transforming), 100A, 400A, 600A.
Overview
ADW2XX series rail type multi-loop power meters are mainly used for measuring the full electric parameters of multiple three-phase circuits,Up to four three-phase loop current inputs can be connected simultaneously.It Can measure voltage and current, power, power factor, phase angle, unbalance, harmonic and other parameters.

Coding Rule

Display


Application

ADW2XX series of multi-channel 3 phase electricity meters can measure 4 channels of 3 phase circuits at most.
Rated current: 5A( secondary transforming), 100A, 400A, 600A.
Paired CTs with specs of 5A/1.25mA, or 100A/20mA, or 400A/100mA or 600A/100mA.
External CTs Connectwith ADW210 Main Body thrrough RJ12 Interface.
Network



Function
1. Full electric parameter measurement of N(1,2,3,4) three-phase circuit, external Current transformer;
2. Monitoring 3 Phase Voltage/Current, Zero sequence Current, Frequency;
3. Monitoring 3 Phase power, total power (active, reactive, apparent);
4. Monitoring three Phase power-factor, total power-factor;
5. Monitoring Voltage/Current Phase Angle, Voltage/Current Degree of unbalance;
6. Monitoring Voltage, Current total Harmonic and 2-31 Fractional harmonics;
7. Record of voltage, current and power extremum of current month and last month;
8. Maximum Current, Maximum power demand and real time Current, real time power demand;

9. 200 event records, Record the action of DIDO;
10. Support over-voltage, over-current, phase failure, DI linkage and other alarm output;
11. 4 time zones 14 Periods rate setting;
12. Four quadrant electric energy,12-month multi rate electric energy;
13. 31 days four quadrant and multi rate electric energy freezing, Positive and negative energy metering;
14. 2 channel Switching inputs, 2 channel Switching outputs, RS485, Active pulse output(Switchable corresponding circuit).

DO/DI Switch Extra Function Module — MK
● 12 channel DI (Digital Input)
● 4 channel DO (Digital Output)


Expanded Communication Module — AWT100
● 4G (Global general module)
● WiFi
● LoRaWAN
● LoRa
● NB-IoT
Dimension



Connect via CTs

Wiring

3-phase 4-wire Wiring of ADW210 monitoring 4 3-phase Circuits

Wiring between ADW210 Main Body and MTL&MK Extra Function Module through RJ45 Interface

Wiring between 1 ADW210 Main Body and 1 AWT100 Communication Module (Attention: In the connection between 1 ADW210 and 1 AWT100 through RJ45 interface, we don’t need Auxiliary Power Supply for AWT100)

Wiring between more than 1 ADW210 Main Bodies and 1 AWT100 Communication Module
(Attention: In the connection between more than 1 ADW210 and 1 AWT100 through RS485 Serial Ports, we need DC24 or DC12V Auxiliary Power Supply for AWT100)